Boiler type Brute Elite BNTV-399

Error code 100

Cause:

Pressure Sensor Fault 

Solution:

-Verify the pressure sensor is a 4-20 mA source.
-Check wiring and correct any possible errors.
-Test the pressure sensor for correct operation.
-Replace the pressure sensor.