nl en de
Select your language

Select country

Errors


Boiler type VSL-160-C

Error code E08

Cause:

U6 boiler temperature sensor circuit interrupted.

Solution:

If the sensor resistance does not correspond, it must be replaced.
If the electrical circuit is damaged, it must be repaired.
if the previous two cases do not apply, replace the power control board