Störungen / Fehler


Kessel Typ Greenstar KBR42-3

Störungscode d3

Ursach:

Temperature high limit defective.
External guard has tripped.
Temperature limiter locked out.

LÖsung:

- Check temperature sensor and leads for interruptions or shorts, and replace if defective.
- Temperature guard TB1 has tripped. Check if jumper across 8-9 or PR-P0 is missing.