nl en de
Select your language

Select country

Errors


Boiler type KB211

Error code Low 24 vac

Cause:

120 vac input to the main control board has dropped below 80 vac.

Solution:

- Check 120 vac supply to the transformer.
- Check wiring connections at the low voltage terminal strip.
- Check the wire size/length to remote devices.
- Replace the transformer.